Total Organic Carbon Analyzer Specification

  • Measuring Range
  • 4 ppb - 30,000 ppm TOC
  • Accuracy
  • 2% or better
  • Application
  • Water quality analysis, wastewater treatment, industrial process monitoring
  • Response Time
  • Within 3 min/sample
  • Test Range
  • 4 ppb - 30,000 ppm TOC
  • Number of Specimens
  • 1 at a time (autosampler optional)
  • Features
  • Automatic calibration, user-friendly interface, data storage
  • Mounting Type
  • Benchtop
  • Resolution
  • 0.01 ppm
  • Frequency
  • 50/60 Hz
  • Interface Type
  • RS232, USB
  • Display Type
  • Large Touchscreen LCD
  • Specimen Size
  • 5-50 mL (sample volume)
  • Power Supply
  • 220V AC, 50/60 Hz
  • Port Size
  • Standard 1/4 inch inlet
  • Equipment Type
  • Total Organic Carbon Analyzer
  • Gas Pressure
  • 0.4 - 0.6 MPa (carrier gas)
  • Automation Grade
  • Automatic
  • Operating Voltage
  • 220V AC
  • Temperature
  • Operating: 10-40C
  • Humidity
  • 85% RH
  • Usage
  • Laboratory, industrial
  • Capacity
  • Automatic sample handler optional
  • Machine Weight
  • Approx. 15 kg
  • Test Speed
  • Up to 10 samples/hour
  • Control Mode
  • Touchscreen control
  • Alarms
  • Leak and pressure alerts
  • Sample Types
  • Suitable for pure, drinking, and wastewater
  • Sample Throughput
  • Up to 50 samples with autosampler
  • Detection Method
  • High-temperature catalytic oxidation with NDIR detection
  • Reagent Type
  • Standard TOC reagents supported
  • Dimensions
  • 480 x 370 x 330 mm
  • Compliance
  • Meets EPA, ISO, and ASTM standards
  • Data Output
  • USB export, Print-out supported
  • Calibration
  • Multi-point automatic calibration
 

Total Organic Carbon Analyzer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

Total Organic Carbon Analyzer About



Experience unrivaled precision with our Total Organic Carbon Analyzer, featuring high-temperature catalytic oxidation and NDIR detection for unparalleled accuracy. Now available at a reduced rate, this exquisite analyzer boasts an autosampler with heroic throughput- up to 50 samples. Procure exceptional results every time, supported by multi-point automatic calibration, USB export, and print-out functionality. Standard TOC reagents, leak and pressure alarms, and robust EPA, ISO, and ASTM compliance ensure your laboratory operates at peak efficiency. Procure this discounted, leading-edge technology for all your water quality needs.

Versatile Usage and Application Spectrum

The Total Organic Carbon Analyzer is engineered for both laboratory and industrial environments. Its automatic, benchtop design allows for effective water quality analysis, wastewater treatment monitoring, and evaluation in industrial processes. From pure water and drinking water to wastewater, this analyzer adapts seamlessly, delivering robust performance for each sample type. With its intuitive touchscreen control and multi-sample handling, it supports diverse applications, making it a must-have for manufacturers, service providers, suppliers, and traders in India.


Export Offers, Sample Policy, and Payment Terms

We extend our offer to global export markets with competitive rates on the Total Organic Carbon Analyzer. For client assurance, samples are available upon request. Secure transactions are supported with flexible payment terms- including advance payments and secure modes tailored to international partners. Our focus is on ensuring efficient supply and satisfaction, whether you are a domestic user or seeking reliable procurement for export. Take advantage of this opportunity to optimize your laboratory at a favorable rate.


FAQ's of Total Organic Carbon Analyzer:


Q: How does the Total Organic Carbon Analyzer ensure measurement accuracy?

A: The analyzer utilizes high-temperature catalytic oxidation combined with NDIR detection, providing measurement accuracy within 2% or better across a range of 4 ppb - 30,000 ppm TOC.

Q: What sample types and applications is this analyzer suitable for?

A: It is designed for pure, drinking, and wastewater samples, making it ideal for laboratory analysis, industrial process monitoring, and wastewater treatment assessments.

Q: What is the process for exporting the Total Organic Carbon Analyzer and are samples available?

A: We offer attractive rates for clients in international markets. Samples can be arranged upon request, and we provide flexible payment terms for seamless procurement.

Q: Where can the analyzer be installed and operated?

A: Its benchtop mounting is perfect for laboratory, industrial, and service provider settings, requiring a power supply of 220V AC within a temperature range of 10-40C.

Q: What are the main benefits of the automatic calibration and autosampler features?

A: Automatic calibration ensures consistent accuracy, while the autosampler enables high throughput-processing up to 50 samples with ease and reducing manual intervention.