Back to top
Aerosol Photometer
Aerosol Photometer

Aerosol Photometer

MOQ : 1 Unit

Aerosol Photometer Specification

  • Humidity
  • 90% RH
  • Interface Type
  • USB, SD Card slot
  • Mounting Type
  • Bench top
  • Frequency
  • 50 Hz
  • Port Size
  • Inlet/Outlet 12 mm OD
  • Number of Specimens
  • Single channel
  • Resolution
  • 0.0001 mg/L
  • Measuring Range
  • 0.0001 - 100 mg/L
  • Gas Pressure
  • 0.1-0.3 MPa
  • Response Time
  • 1 s
  • Automation Grade
  • Automatic
  • Display Type
  • 7-inch LCD Touch Screen
  • Application
  • Leak detection & filter integrity testing
  • Features
  • Portable, user friendly, real-time data display
  • Operating Voltage
  • AC 220V
  • Test Range
  • 0.0001 - 100 mg/L
  • Temperature
  • 10C - 40C
  • Power Supply
  • AC 220V, 50 Hz
  • Equipment Type
  • Aerosol Photometer
  • Accuracy
  • 5%
  • Usage
  • Cleanroom/HEPA filter/laminar flow cabinet validation
  • Capacity
  • Continuous sampling
  • Machine Weight
  • 7 kg
  • Test Speed
  • Adjustable, up to 60 tests/hour
  • Control Mode
  • Touch screen digital control
  • Data Storage
  • Internal memory, exportable via USB
  • Sampling Flow Rate
  • 28.3 L/min
  • Light Source
  • Laser Diode
  • Alarm
  • Visual and audible alarm for over-limit detection
  • Operating Environment
  • Indoor, dust-free, non-corrosive atmosphere
  • Dimensions
  • 300 mm x 280 mm x 150 mm
  • Calibration
  • Factory calibrated, user calibration supported
  • Enclosure Material
  • Powder-coated steel
 

Aerosol Photometer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

Aerosol Photometer About



Discover the hot-selling, latest Aerosol Photometer-a pivotal instrument famed for its ravishing performance in leak detection and filter integrity testing. Engineered with advanced laser diode technology, this portable device features visual and audible alarms for over-limit detection, a 7-inch LCD touch screen for intuitive operation, and internal data storage exportable via USB. Boasting fast sample processing speeds of up to 60 tests per hour and robust powder-coated steel construction, it is ideal for cleanroom, HEPA filter, and laminar flow cabinet validation. Now available at clearance pricing from India's leading manufacturer, supplier, and service provider.

Versatile Use Across Filtration Integrity Testing

The Aerosol Photometer is essential for both specific and general applications. It is designed exclusively for leak detection and the integrity testing of high-efficiency filters. Commonly used in cleanrooms, laminar flow cabinets, and HEPA filter validation, this pivotal unit ensures compliance in dust-free, controlled environments. Its robust design and automatic features streamline routine testing, making it indispensable in research facilities, pharmaceutical production, and industrial air quality management.


Sample Availability and Order Fulfillment

Sample requests for the Aerosol Photometer are promptly addressed upon arrival of inquiries. Our clear sample policy ensures potential buyers can evaluate performance before purchase. Standard samples are shipped after swift order processing, guaranteeing timely delivery and satisfaction. With substantial supply ability, even bulk orders are handled efficiently and orders are processed seamlessly. This commitment to service underscores our standing as a trusted manufacturer and supplier in the Indian market.


FAQ's of Aerosol Photometer:


Q: How does the Aerosol Photometer function during filter integrity testing?

A: The Aerosol Photometer operates by using a laser diode to measure particle concentration in real-time, providing immediate assessment of filter leaks and overall integrity. The system delivers quantitative results with high accuracy and an adjustable test speed.

Q: What data management features are included with this photometer?

A: It offers internal memory for data storage, with easy data export options via USB or SD card. This allows users to efficiently transfer and analyze test results for documentation and compliance reporting.

Q: Where can the Aerosol Photometer be effectively utilized?

A: This equipment is most effective in controlled, dust-free, non-corrosive indoor environments such as cleanrooms, research labs, pharmaceutical manufacturing, and facilities requiring regular HEPA filter inspection.

Q: What is the process for calibrating this instrument?

A: The Aerosol Photometer comes factory-calibrated but also supports user calibration for ongoing accuracy. Calibration instructions are provided in the user manual to ensure precise and reliable results.

Q: What are the benefits of using a ravishing, automatic touch screen photometer?

A: This advanced, automatic photometer streamlines leak detection, enhances user safety with its over-limit alarms, and offers user-friendly controls for a hassle-free testing experience, making it pivotal in maintaining air quality standards.